Novus myPCLab EN Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 9
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
myPCLab
NOVUS AUTOMATION 4/9
0-50 mV WIRING
Connections of channel 1 are on terminals 6 and 7. For channel 2 on terminals 2 and 3.
Observe indicated polarity.
0-10 V WIRING
Linear voltage signals from 0 to 10 V can only be connected to channel 1, terminals 5 and 6.
Observe indicated polarity.
DRY CONTACT DIGITAL INPUT WIRING
Digital signals are connected to channel 3, terminals 1 and 2.
The contact connected to digital input must not have any electrical voltage.
VOLTAGE DIGITAL INPUT WIRING
Digital signals are connected to channel 3, terminals 1 and 2. Observe indicated polarity.
Voltage levels applied to this channel must be within the specified limits. See “Specifications”.
Seitenansicht 3
1 2 3 4 5 6 7 8 9

Kommentare zu diesen Handbüchern

Keine Kommentare